Operation - Maintenance
Dispensit
1092
332089B
EN
Patented meter and dispense system for precise one-component micro-dispensing. Not for
use in explosive atmospheres.
2000 psi (14 MPa, 138 bar) Maximum Outlet Fluid Working Pressure
Metal Sleeves: 1200 psi (8 MPa, 83 bar) Maximum Material Inlet Pressure
Plastic Sleeves: 400 psi (2.8 MPa, 28 bar) Maximum Material Inlet Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Working Pressure
110°F (43°C) Maximum Ambient Temperature
150°F (65°C) Maximum Operating Temperature
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Cycle Detection and Luer Lock Outlet Shown
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where
applicable.
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just
a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.
•
•
•
•
Do not point gun at anyone or at any part of the body.
Do not put your hand over the dispense outlet.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow Pressure Relief Procedure in this manual, when you stop dispensing and before cleaning,
checking, or servicing equipment.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•
•
•
•
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Always wear impervious gloves when spraying or cleaning equipment.
If this equipment is used with isocyanate material, see additional information on isocyanates in Iso-
cyanate Conditions Section of this manual.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
•
•
•
•
Protective eyewear
Clothing and respirator as recommended by the fluid and solvent manufacturer
Gloves
Hearing protection
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent
fire and explosion:
•
•
Use equipment only in well ventilated area.
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop
cloths (potential static arc).
•
•
Keep work area free of debris, including solvent, rags and gasoline.
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes
are present.
•
•
•
Ground all equipment in the work area. See Grounding instructions.
Use only grounded hoses.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
332089B
3
Warnings
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause elec-
tric shock.
•
•
•
•
•
Turn off and disconnect power cord before servicing equipment.
Use only grounded electrical outlets.
Use only 3-wire extension cords.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
•
Do not leave the work area while equipment is energized or under pressure. Turn off all equipment
and follow the Pressure Relief Procedure in this manual when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
•
•
•
•
•
Do not alter or modify equipment.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•
•
•
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.
PLASTIC PARTS CLEANING SOLVENT HAZARD
Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. Many
solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property
damage. See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent
manufacturer’s warnings.
4
332089B
Isocyanate Conditions
Isocyanate Conditions
•
Keep the ISO lube pump reservoir (if installed) filled
with Graco Throat Seal Liquid (TSL), Part 206995.
The lubricant creates a barrier between the ISO and
the atmosphere.
Spraying or dispensing materials containing isocya-
nates creates potentially harmful mists, vapors, and
atomized particulates.
•
•
Use moisture-proof hoses specifically designed for
ISO, such as those supplied with your system.
Never use reclaimed solvents, which may contain
moisture. Always keep solvent containers closed
when not in use.
Read material manufacturer’s warnings and material
MSDS to know specific hazards and precautions
related to isocyanates.
•
Always lubricate threaded parts with ISO pump oil
or grease when reassembling.
Prevent inhalation of isocyanate mists, vapors, and
atomized particulates by providing sufficient ventila-
tion in the work area. If sufficient ventilation is not
available, a supplied-air respirator is required for
everyone in the work area.
Changing Materials
•
When changing materials, flush the equipment mul-
tiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing.
Check with your material manufacturer for chemical
compatibility.
•
•
To prevent contact with isocyanates, appropriate per-
sonal protective equipment, including chemically
impermeable gloves, boots, aprons, and goggles, is
also required for everyone in the work area.
Material Self-ignition
Some materials may become self-igniting if applied
too thickly. Read material manufacturer’s warnings
and material MSDS.
Moisture Sensitivity of
Isocyanates
ISO will react with moisture (such as humidity) to form
small, hard, abrasive crystals, which become sus-
pended in the fluid. Eventually a film will form on the sur-
face and the ISO will begin to gel, increasing in viscosity.
If used, this partially cured ISO will reduce performance
and the life of all wetted parts.
NOTE: The amount of film formation and rate of crystal-
lization varies depending on the blend of ISO, the
humidity, and the temperature.
To prevent exposing ISO to moisture:
•
Always use a sealed container with a desiccant
dryer in the vent, or a nitrogen atmosphere. Never
store ISO in an open container.
332089B
5
Grounding
Grounding
Overview
This single-component meter and dispense device
accurately meters liquid and semi-paste materials.
The machine is ideal for a single-component application
requiring very small and precise shots.
This product must be grounded. In the event of an elec-
trical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric cur-
rent.
The ratio of the pneumatic cylinder area to pump shaft
area provides the adjustable pressure intensification
needed to move the liquids through the needle with a
flow rate suitable for production requirements.
Metering valve: attach ground wire from grounding lug
to true earth ground. See Component Identification
starting on page 8.
The complete system is enclosed. See Sequence of
Fluid hoses: use only electrically conductive hoses.
Feed system components: attach ground wire from
grounding lug to true earth ground. See feed system
manual for grounding points.
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
grounding continuity.
6
332089B
Optional Cycle Detection Sensors
h. PX-RET signal is made and Metering Rod is
down (Dispense Material Complete).
Optional Cycle Detection
Sensors
i. Solenoid-Open Spool Valve/EXTend is deacti-
vated.
The sensors are magnetic reed switches and must be
connected to an electrical control package. The sensors
wires are #24 awg and have 9 foot (2.7 meters) flying
leads. An LED on the sensor illuminates to indicate a
change in state.
j. Solenoid-Close Spool Valve/RETract is acti-
vated.
k. PX-OSV signal drops Spool shifts from the Dis-
pense Position to the Reload Position and
Metering Rod Retracts upward (Reloading
Material).
Suggested Sequence of Operation (See
page 16).
l. PX-CSV signal is made.
m. PX-EXT signal is made.
•
•
The Valve Outputs (supplied by others) consisting of
two power valves or one dual power valve [Sole-
noid-Close Spool Valve/RETract (Green Tube 1/4 in.
OD) and Solenoid-Open Spool Valve/EXTend (Yel-
low Tube 1/4 in.OD)]. Connect each Quick Discon-
nect (5/16-24 fitting) to respective power valve port.
Other needed Input would include some type of
Start device (Foot Switch or Control Box) (supplied
by others)
n. Dispense Valve is ready for next Start device
signal.
•
1. Home (Reload) Position
a. Solenoid-Close Spool Valve/RETract is acti-
vated.
b. Solenoid-Open Spool Valve/EXTend is deacti-
vated.
c. PX-EXT and PX-CSV signal have been made.
d. PX-RET and PX-OSV signal is not made.
e. Metering Rod is Retracted.
2. Shot Procedure
a. Start device signal is made.
b. Solenoid-Close Spool Valve/RETract is deacti-
vated.
c. Solenoid-Open Spool Valve/EXTend is acti-
vated.
d. PX-EXT and PX-CSV signal drops off.
e. Spool shifts from the Reload Position to the Dis-
pense Position.
f. PX-OSV signal is made.
g. Metering Rod Extends downward (Dispensing
Material).
332089B
7
Component Identification
Component Identification
Typical System Configurations
OFF
START
HAND AUTO
SW-2
PB-1
G-1
G-2
AUXILIARY
PRESSURE
TR-1
SYSTEM
PRESSURE
DISPENSE
TIMER
POWER
OFF ON
REG-1
REG-2
SW-1/PL-1
Valve
Liquid Control
R
Top View of Controls
R
Controls
System shown with optional 4104A controls
FIG. 1
8
332089B
Component Identification
Typical Feed System Components
5 Gallon Pail Cover
with Diaphragm
Pump and Agitator
5 Gallon Pail Cover
with Diaphragm Pump
20 oz Cartridge Feed
with Mounting Post
1 Gallon Ram
and Pump
F
WARNING
DO NOT SERVICE WITHOUT
REMOVING AIR PRESSURE AND
WEARING SAFETY GLASSES.
psi
5 Gallon Pail Cover
with 5:1 Transfer
Pump
5 Gallon Pail Cover
with Diaphragm
Pump
5 Gallon Ram and
11:1 Transfer Pump
FIG. 2
332089B
9
Component Identification
Typical Feed System Components (continued)
5 Gallon Tank with Diaphragm Pump and Stand
5 Gallon Tank with 5:1 Pump and Stand
15
psi
15
psi
10 Gallon Tank with Diaphragm Pump, Agitator,
Vacuum, and Stand
10 Gallon Tank with 5:1 Pump, Agitator, Vacuum,
and Stand
FIG. 3
10
332089B
Component Identification
Metering Valve
T
G
S
L
E
F
H
M
C
J
K
D
A
Z
Key:
A
C
D
E
F
G
H
J
Material Inlet
Grounding Lug
Spool
Metering Rod
Oil Cup Retaining Block
Extend Air Inlet
K
L
Reload Air Inlet
Extend Air Flow Adjustment
Knob
Retract Air Flow Adjustment
Knob
Shot Size Locking Ring
Shot Size Adjuster
Luer Lock Outlet
M
S
T
Z
Retract Air Inlet
Dispense Air Inlet
FIG. 4
332089B
11
Setup
Setup
5. Connect each 1/4 in. outside diameter supplied air
line to the corresponding control solenoid. See
2.
3. Perform Setup procedure for feed system compo-
nents. See feed system manual(s).
6. Connect chemical lines from feed system to meter-
ing valve material inlets. See Component Identifi-
4. Place an in-line air pressure regulator, air-water
separator/filter, and shut-off/bleed valve between
the air supply and the control solenoids.
Typical Installation
User Supplied
Air Shut-off and Bleed Valve
Air Supply
Air-Water Separator/Filter
Air Pressure Regulator
Control Solenoids
Material Tank (optional)
Pump
Metering Valve
Fluid Shut-Off Valve
FIG. 5
12
332089B
Setup
Valve Mounting Diagram
As desired, use the following diagram to mount the
metering valve.
A
B
CYCLE DETECTION
DIMENSION NON CYCLE DETECTION
A
B
8.38
4.19
9.13
4.56
SHOT SIZE
ADJUSTMENT
WITH LOCK
0.688
EXTEND
ADJUSTABLE
FLOW CONTROL
WITH LOCK
0.688
(2) #F (.257 DIA.) DRILL THRU
RETRACT
ADJUSTABLE
FLOW CONTROL
WITH LOCK
(2) .189/.191DIA. DRILL THRU
GROUND STUD
C
RETRACT/CLOSE
DISPENSE VALVE
EXTEND/OPEN
DISPENSE VALVE
D
R
E
Dispensit R
USA
MODEL 1092-10A
SN XXXXXX
1.53
LUER LOCK
NEEDLE MOUNT
MATERIAL OUTLET
1
4
NPT FEMALE
MATERIAL INLET
2 = 1" METERING STROKE
4 = 2" METERING STROKE
6 = 3" METERING STROKE
1092-10A-_
DIMENSION
0.59
0.88
1.75
4
6
2
C
D
E
11.00
1.750
2.500
15.63
3.250
2.250
18.75
1.750
2.500
0.56
FIG. 6
332089B
13
Startup
Startup
1. Lubricate the metering rod port in the oil cup retain-
ing block and fill the spool valve ports with compati-
ble lubricant such as mesamoll or silicone oil.
Metering Rod Port
Spool Valve Ports
FIG. 7: Top View of Metering Valve with Top Section
Removed
2. Pressurize the feed systems connected to the
metering valve to prime the system. See Technical
3. Dispense several full stroke shots until material is
air-free and has good shut-off at the nose.
NOTE: Very viscous, compressible materials may con-
tinue to droll after system is primed. Reduce flow rate as
required to produce air-free dispense.
NOTE: Very thin materials may require tilting the valve
greater than 45 degrees and dispensing shots until
material is air-free. Remove oil from cups before pro-
ceeding.
14
332089B
Adjusting the Shot Size
Adjusting the Shot Size
1. Rotate the shot size locking ring counterclockwise to
loosen.
2. Rotate the shot size adjuster to adjust shot size.
3. Rotate the shot size locking ring clockwise to
tighten.
4. Dispense into waste container to test shot size.
5. Repeat until desired shot size is achieved.
332089B
15
Operation
Operation
The operation of the 1092 metering valve is controlled
by an external source. If a 4104A Control Box was pur-
chased, see the 4104A Control Box manual for opera-
tion instructions.
Step 2: Shift
Sequence of Operation
Step 1: Reload
•
•
•
•
The balanced spool shifts to the dispense position
Material path to the needle is opened
Material feed inlet port is blocked
Metering rod remains in the retracted position
Step 3: Dispense
•
•
•
Spool shifts to the right
Material feed inlet is opened
Material is transferred into the metering chambers
by a pressurized feed system
•
•
Outlet port is blocked
Metering rod is retracted to a precise position deter-
mining the volume of each material
•
•
Metering rod extends
Material is dispensed from the metering chamber
into the needle
Upon completion of the dispense stroke, the metering
rod and spool shifts back to the reload position.
16
332089B
Pressure Relief Procedure
Pressure Relief
Procedure
Maintenance
Perform the following procedures once a shift.
1. Retract the metering rods. See the 4104A Control
Box manual.
page 18.
2. Close the fluid shut-off valve.
3. Remove needle.
Material Reservoirs
Check material levels and refill as necessary. Ensure
that the material reservoirs are properly vented.
4. Dispense 5 shots. Shots should be at least 75% of
the full stroke.
Air Dryer
5. Extend the metering rod into the tubes. If Graco
controls are provided with the system, see the
4104A Controls manual.
Check the condition of the desiccant air dryer. Replace
as necessary.
Metering Rod Port
6. Close the incoming air shut-off/bleed valve that sup-
plies air to the metering valve.
Lubricate with compatible lubricant such as mesamoll or
7. Close the incoming air shut-off/bleed valve that sup-
plies the feed system. Refer to feed system manual
for pressure relief procedure.
Spool Valve Port
Fill with compatible lubricant such as mesamoll or sili-
Shutdown
2. Inspect the metering rod for material buildup. Clean
as necessary.
3. Lubricate the metering rod with compatible lubricant
such as mesamoll or silicone oil.
4. Remove needle and replace with an airtight cap.
332089B
17
Troubleshooting
Troubleshooting
ing any troubleshooting procedure.
Problem
Cause
Solution
Metering valve stalling and no mate- Blocked needle
rial being dispensed despite ade-
quate input pressure
Check needle for cured material,
replace as required
Flow control valve closed
Open needle
Metering valve not discharging nor-
mal or full volume
Low material level in reservoirs
Fill material reservoirs and prime the
machine
Air in material tank
Fill reservoir and prime machine
Replace the spool valve
Material leaks past spool valve
Spool will not actuate
Spool valve worn or damaged
Low air pressure
Increase air pressure to approxi-
mately 20-30 psi
Cured material on spool
Seals are worn
Check spool for cured material,
replace as required
Replace seals
Schematics
For standard machines, the schematics will be
included in the 4104A Parts manual.
For custom machines, the schematics will be included
in the assembly drawings manual.
18
332089B
Rebuild
Rebuild
Cutaway Front View
SCREW
1
2
DRIVE cylinder end cap
assembly
DISPENSE piston
NA
3
u-cup seal
4
O-Ring
5
RETAINING ring
WASHER
6
7
u-cup seal
8
FLOW control
DIVORCED section
METERING rod
SEAL cup
9
10
11
12
posipak SEAL
dispense sleeve
13
14
27
O-Ring
SCREW
15
16
Tee Fitting
17
SCREW
END cap
18
19
24
SCREW
20
21
22
23
24
Spool shift piston
SEAL retainer
posipak SEAL
Spool/sLEEVE ASSY
SEAL, plate, cups
MAIN body
26
27
Material Outlet (needle not shown)
Material Inlet (port on side of block)
FIG. 8
2. Turn off the material inlet pressure to the 1092.
Disassembly
3. Cycle the valve a few times to remove residual
material pressure.
4. Turn off the air pressure to the 1092.
5. Remove the air pressure lines from the air supply
Tee Fittings (17 & 17). Do not remove the fittings
themselves.
dure.
1. For models with cycle detection sensors, discon-
nect the electrical power from the cycle detection
sensors. Note the position of the sensors, then
remove them by loosening the set screws and slid-
ing them out carefully.
6. Remove the material inlet line from the Inlet Block.
7. Remove the dispense valve from its mounting.
332089B
19
Rebuild
8. Remove the Screws, that hold the Needle Block
Assembly to the Inlet Block. The Needle Block
Assembly may look different than the illustration as
it may have multiple needles. If the needle is a
removable #10-32 or Luer Lock type consider
removing it to protect it.
23. Remove the Screws (20) that hold the Seal Plate
Cups (26) to each side of the Main Body (27). The
Seal Retainer Washers (22), and the Posipak Seals
(23) will come off with the Seal Plate Cups.
24. Push the Spool Assembly (24) out with a finger. If it
does not slide out, tap it gently using a wood or
plastic dowel.
9. Remove and inspect the gasket. If it is in good con-
dition you can re-use it; otherwise, discard it and
secure a replacement.
Assembly
10. Remove the Screws that attach the Inlet Block to the
Main Body (27). If necessary for cleaning, remove
any adapter fitting (not shown) that may be installed
in the Inlet Block.
11. Remove the o-rings.
lowing procedure.
12. Remove the four Screws (18) and the End Cap (19)
on each side of the valve. Disconnect the short air
line sections on each side.
Clean all valve parts with an appropriate solvent prior to
reassembly. Always install new, lubricated o-rings and
seals when assembling the valve. Use Krytox 203GPL
(part number 84/0200-K3/11) for lubricating valve parts
including seals and o-rings. Check the Metering Rod
(11), Dispense Sleeve (14), and Sleeve Assembly (24)
for wear and if they are worn secure replacements
before proceeding.
13. Remove the two Spool Shift Pistons (21) from the
End Caps (19). They should come out easily but if
not use low pressure (less than 2 psi or 0.1 bar) air
at the Tee Fitting (17) to move them. Remove the
U-cup seals (4) from the Spool Shift Pistons (21).
14. At the top of the valve, remove the four Screws (1)
and remove the Drive Cylinder End Cap Assembly
(2). Disconnect the air line from the Tee Fitting (17).
Carefully install new U-cup and Posipak seals so that
they are not pinched or torn. Do this by making sure
they are lubricated, and by tucking the lips of the seal
inward before uniformly pushing them into position.
15. Separate the Dispense Piston (3) from the Metering
Rod (11).
Install the Seal Plate Cups on the Main Body
16. Remove the two U-cup seals (4) from the Dispense
Piston (3).
1. Install a lubricated O-ring (15) on the left side of the
Main Body (3) next to the sleeve part of the Spool
Assembly (24).
17. Remove O-ring (5) from the Divorced Section (10).
18. Remove the Screws (16) that hold the Divorced
Section (10) to the Main Body (27) and remove
O-ring (15).
2. Install two lubricated Posipak Seals (23) in the left
Seal Plate Cup (26) so that the O-ring side of both
Posipaks will be facing the Main Body (27). Be sure
to tuck the lip of the Posipak into its cavity to avoid
tearing it.
19. Remove the Metering Rod (11) and Seal Cup (12)
from the Divorced Section (10).
3. Position the left Seal Cup Plate (26) with the oil cup
upwards and slide it over the Spool part of the Spool
Assembly (24) with the counterbore for the Seal
Retainer (22) facing out. Slide the Seal Retainer
(22) over the Spool and install two Screws (20).
20. Push the Seal Cup (12) off the Metering Rod and
remove the Posipak seal (13).
21. Use snap ring pliers to remove Retaining Ring (6)
and Washer (7) from the Divorced Section (10).
Remove the U-cup seal (8).
4. Repeat steps 3, 4 and 5 for the right side Seal Plate
Cups.
22. Remove the Dispense Sleeve (14) from the Main
Body (27).
20
332089B
Rebuild
Build the Divorced Section and Mount to the Main
Body
16. Install two lubricated U-cup Seals (4) onto the Dis-
pense Piston (3) with the upper seal lip up and the
lower seal lip down as shown.
5. Place lubricated U-cup Seal (8) lip side up into the
Divorced Section (10). Place the Washer (7) over it,
and reinstall the Retaining Ring (6).
17. Lubricate the bore of the Drive Cylinder End Cap
Assembly (2) and insert the Dispense Piston (3)
flush with the end of it, tucking the lip of the upper
U-cup Seal (4) so that it is not damaged.
6. Lubricate and insert the Metering Rod (11) into the
Divorced Section (10) from the bottom and push up
carefully through the U-cup seal (8).
18. Slide the Metering Rod (11) into the key slot on the
piston and slide the Drive Cylinder End Cap Assem-
bly (2) down onto the Divorced Section (10) and
carefully over the O-ring (5).
7. Install the Seal Cup (12) into the Divorced Section
(10) over the Metering Rod (11) and slide the lubri-
cated Posipak Seal (13) over the Metering Rod
keeping the O-ring side of the Posipak facing down.
The ends of the Metering Rod (11) should be pro-
jecting from the upper and lower ends of the
Divorced Section.
19. Align the screw holes in the Drive Cylinder End Cap
Assembly (2) with the corresponding holes in the
Divorced Section (10) and install the four Screws
(1). Tighten the screws in a cross pattern gradually
to prevent binding due to misalignment (like you
would tighten lug nuts on a car tire).
8. Lubricate the dispense sleeve bore in the Main
Body (27). Insert the Dispense Sleeve (14) into the
Main Body (27). Check for threads that may be in
the inside of the sleeve due to tapping during
removal and make sure these are at the top.
20. Install the short air lines on the left and right sides of
the valve.
Install the Needle Block Assembly
9. Install a lubricated O-ring (15) around the Dispense
Sleeve (14).
21. Install any removable needles that were previously
removed.
10. Holding the Divorced Section (10) and using the
projecting Metering Rod (11) as a guide slide the
Metering Rod (11) into the Dispense Sleeve (14)
and install the Divorced Section (10) against the
Main Body (27). Install the Screws (16).
22. If your valve has cycle detection, slide the cycle
detection sensors into the slots on the end caps and
secure with the set screws. Do not overtighten the
set screws as the sensors may be damaged.
23. Connect the air lines.
Mount the Valve End Caps to the Seal Plate Cups
11. Install a lubricated U-cup Seal (4) onto the left Spool
Shift Piston (21) with lip side out as shown. Lubri-
cate the bore in the End Cap (19). Slide the piston
into the left End Cap (19) tucking the lip of the seal
into the End Cap carefully.
24. Perform the Dry Run, Loading & Priming and Output
Verification procedures. Perform Operation Adjust-
ment procedures if required.
12. Install the Piston/End Cap onto the left Seal Plate
Cup (26) using four Screws (18). Tighten the screws
in a cross pattern gradually to prevent binding due
to misalignment (like you would tighten lug nuts on a
car tire).
13. Push the Spool into the left side until it contacts the
piston.
14. Repeat steps 13 and 14 for the right side.
Install the Drive Cylinder
15. Install lubricated O-ring (5) on top of the Divorced
Section (10).
332089B
21
Electrical Requirements (Cycle Detection Option)
Electrical Requirements (Cycle Detection Option)
LABEL PX-EXT
9' CABLE
BROWN (+24DC)
WHITE (SIGNAL)
SHOT SIZE
ADJUSTMENT
WITH LOCK
LABEL PX-RET
9' CABLE
EXTEND
ADJUSTABLE
FLOW CONTROL
WITH LOCK
BROWN (+24DC)
WHITE (SIGNAL)
RETRACT
ADJUSTABLE
FLOW CONTROL
WITH LOCK
GROUND STUD
YELLOW
GREEN
RETRACT/CLOSE
DISPENSE VALVE
EXTEND/OPEN
DISPENSE VALVE
LABEL PX-CSV
9' CABLE
LABEL PX-OSV
9' CABLE
BROWN (+24DC)
WHITE (SIGNAL)
BROWN (+24DC)
WHITE (SIGNAL)
R
Dispensit R
USA
MODEL 1092-10A
SN XXXXXX
LUER LOCK
NEEDLE MOUNT
MATERIAL OUTLET
1
4
NPT FEMALE
MATERIAL INLET
FIG. 9
22
332089B
Technical Data
Technical Data
NOTE: See feed system manuals for dimensions, weights, and wetted parts lists for those components. Dimensions,
weights, and wetted parts for components not covered in component feed system manuals and for combined assem-
blies are listed below.
Maximum Ambient Temperature. . . . . . . . . . . . . . . . . . . . 110°F (43°C)
Maximum Operating Temp . . . . . . . . . . . . . . . . . . . . . . . . 150°F (65°C)
Maximum Outlet Fluid Working Pressure . . . . . . . . . . . . . 2000 psi (14 MPa, 138 bar)
Maximum Air Working Pressure . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Minimum Air Working Pressure . . . . . . . . . . . . . . . . . . . . 70 psi (480 kPa, 4.8 bar)
Maximum Material Inlet Pressure. . . . . . . . . . . . . . . . . . . Metal Sleeves: 1200 psi (8 MPa, 83 bar)
Plastic Sleeves: 400 psi (2.8 MPa, 28 bar)
Supplied Air Requirements. . . . . . . . . . . . . . . . . . . . . . . . 1 to 3 cfm at 80 psi to 100 psi
Shot Size Range (depending on metering rods selected) 0.024 cc to 9.600 cc
Maximum Cycle Rate (application dependent, heat
required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Up to 60 cycles per minute
Dimensions:
Height (to end of material inlet block):
1092-10A-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.53 in. (395 mm)
1092-10A-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.16 in. (436 mm)
1092-10A-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.28 in. (515 mm)
Length:
Non Cycle Detection . . . . . . . . . . . . . . . . . . . . . . . . . 8.38 in. (213 mm)
Cycle Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.13 in. (232 mm)
Width:
Single Needle Outlet (Standard) . . . . . . . . . . . . . . . . 1.75 in. (45 mm)
Graco-supplied Feed System Assemblies
(depends on selected options):
Smallest: 22.5 x 10 x 4 in. (572 x 254 x 102 mm)
Largest: 60 x 28 x 19 in. (1524 x 711 x 483 mm)
Weight
1092-10A-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 lb (2.72-3.18 kg)
1092-10A-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11 lb (4.54-4.99 kg)
1092-10A-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15 lb (6.35-6.80 kg)
Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metering Valve: Hardened steel, 303/304, 404, UHM-
WPE, Tungsten, carbide, fluoroelastomer, EPDM,
PTFE, Acetal
Graco-supplied Feed System Hoses and Fittings: Mild
steel, 303/304, PTFE, buna, polyethylene, polypropyl-
ene
Graco-supplied Tanks: Polyethylene, 303/304, mild steel
332089B
23
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Toll Free: 1-800-746-1334 or Fax: 330-966-3006
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 332089
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2010, Graco Ohio Inc. All Graco manufacturing locations are registered to ISO 9001
Revised January 2015
|