HP Hewlett Packard Computer Drive SAN Array 1000 User Manual

hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Overview  
The HP StorageWorks Modular SAN Array 1000 is a 2 Gb Fibre Channel storage system designed for the entry-  
level to mid-range Storage Area Network (SAN). Designed to reduce the complexity, expense and risk of SAN  
deployment, the msa1000 is a scaleable, high performance storage system built with investment protection in  
mind. The modular design of the msa1000 allows the user to easily add storage capacity on an as needed basis.  
HP StorageWorks Modular SAN  
Array 1000  
The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1” universal disk  
drives in a single 4U rackmount cabinet. More storage can be easily deployed with the addition of up to two  
StorageWorks 4314 Enclosures for a maximum storage capacity of 6 TB when using the new 146 GB drives. The  
msa1000 provides the latest 2 Gb Fibre Channel technology to the hosts. Besides the single port 2 Gb Fibre  
Channel I/O module that comes standard, there is an optional 3-port 2 Gb Fibre Channel hub that also fits inside –  
an ideal low cost solution for simple 2-node clustering. There is also a newly introduced 8-port switch that mounts  
internally, featuring a low cost per port option that saves rack space. The msa1000 provides Ultra3 SCSI  
connections to the hard drives and uses the HP Universal 1” Ultra2, Ultra3, and/or Ultra320 drives. By utilizing  
SCSI drives, the msa1000 lowers the total cost of ownership and extends the customers hardware investments  
into the future.  
An alternative firmware version, installed in place of the standard version, now enables support for OpenVMS and  
Tru64 UNIX. A copy of this alternative firmware ships with the msa1000 and is also downloadable at no charge  
from the HP msa1000 Web site. It replaces the existing firmware that ships with the MSA1000. Included with the  
firmware will be instructions on the procedure to upgrade the firmware in either a Tru64 UNIX or an OpenVMS  
environment  
High performance controller(s) built on DAS to SAN {DtS} architecture for maximum investment protection  
4U rackmount design combining both the controller and disk shelf  
2 Gb Fibre Channel host connections  
The msa1000 offers the following  
key features  
Ultra3 SCSI connections to drives  
Support for HP Ultra2, Ultra3, and Ultra320 Universal 1” Drives  
Scaleable from 3 to 42 drives via HP StorageWorks 4200/4300 Enclosures  
Support for 1 Gb and 2 Gb Fibre Channel fabrics  
Multiple clusters and/or single server access to an individual msa1000.  
Whats new  
Support for concurrent access by servers with OpenVMS and Tru64 UNIX operating systems  
Redundancy (if present) retained while expanding number of drives or enlarging LUNs  
New 3-port embedded hub or 8-port switch option  
Ability to add an additional storage drive enclosure (42/4300) to a msa1000 without power cycling unit  
Support for larger and/or faster drives allowing total capacity to scale to 6 TB  
DS10, DS10L, DS20E, DS25  
ES40, ES45, ES47, ES80  
Supported Alpha servers  
GS80, GS160, GS320, GS1280  
DA-11621  
Canada — Version 2 April 15, 2003  
 
1
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Models  
HP StorageWorks Modular SAN  
Array 1000 For Alpha Server  
Systems w/ OpenVMS and Tru64  
UNIX  
msa1000, with 256MB cache  
201723-B22/  
3R-A4328-AA  
msa1000 Controller, with 256MB cache  
256 MB Cache Module for Controller  
msa Fibre Channel I/O Module  
218231-B22/  
3R-A4330-AA  
254786-B21/  
3R-A3954-AA  
218960-B21/  
3R-A2969-AA  
msa SAN Switch 2/8 (integrated)  
288247-B21/  
3R-A4289-AA  
msa HUB 2/8 (integrated)  
286763-B21/  
3R-A3907-AA  
FCA2354 Host Adapter (Open VMS/Tru64 UNIX)  
2 Gb SFP SW Transceiver Kit  
261329-B21/  
DS-KGPSA-DA  
221470-B21/  
3R-A2973-AA  
HP StorageWorks Enclosure Model 4314R  
HP StorageWorks Dual bus Enclosure Model 4354R  
190209-001/  
DS-SL13R-AA  
190211-001/  
DS-SL13R-BA  
DA-11621  
Canada — Version 2 April 15, 2003  
3
 
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
MSA1000 Components  
With the following components, your storage capacity and performance can be scaled to new levels  
The 4U cabinet houses up to fourteen 1” Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives. Each  
Modular SAN Array 1000  
msa1000 includes the following standard components: (1) msa1000 Controller, (1) msa Fibre Channel I/O Module  
with a single SFP, dual hot pluggable fans/power supplies and power cables, (2) 3’ VHDCI to VHDCI SCSI cables  
to connect expansion enclosures, documentation and a CD Kit containing firmware upgrade code for Tru64 and  
OpenVMS and a support software CD.  
The modular design of the msa1000 makes it possible to add redundant controllers, redundant single port Fibre  
Channel I/O Modules, 3-port hub, or msa SAN switch 2/8 and storage expansion enclosures.  
The msa1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256 MB  
read/write battery-backed cache (expandable to 512 MB per controller). One msa1000 Controller is included with  
the msa1000; a redundant msa1000Controller is an option.  
msa1000 Controller  
Redundant controller support with mirrored cache  
Fabric, Private Loop & Public Loop Support  
Auto Negotiated F, FL & L Port Login  
RAID 0, 1, 1+0, 5 and ADG  
Key Features  
2 Gb/1 Gb Frequency Agile  
Primary & Secondary Inter-Controller Link (ICL)  
configurable with Command Line Interface (CLI)  
Online RAID Level Migration: allows for online post-configuration change to  
RAID level without destroying data or volume information.  
msa1000 Controller  
Management Features  
Online Capacity Expansion: lets you add storage to an operational  
msa1000reducing expensive server downtime.  
Global Online Spare: reduces the risk of data loss by facilitating automatic  
rebuilds after a drive failure  
Several fault tolerant configurations, which keep data available and servers  
running while drives are being replaced, are supported including:  
Fault Tolerance  
Advanced Data Guarding (RAID ADG): Allocates the equivalence of two  
parity drives across multiple drives and allows simultaneous write  
operations.  
Distributed Data Guarding (RAID 5): Allocates parity data across multiple  
drives and allows simultaneous write operations.  
Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive  
array to data and the other half to mirrored data, providing two copies of  
every file.  
Minimizes downtime, reconstructs data, and facilitates a quick recovery  
from drive failure  
Fault Recovery  
Online Spares: If a failure occurs, recovery begins with an online spare and  
data is reconstructed automatically. Multiple online spares can be  
assigned per array and used across multiple arrays. It is also possible to  
assign different online spares across different arrays.  
Array Accelerator: Onboard, battery-backed cache memory protects data in  
the event of a power failure. In the unlikely event of a controller failure, the  
battery-backed cache will save critical user data for up to three days  
Provides a single 2 Gb Fibre Channel connection per controller from the host side into the msa1000. The msa  
Fibre Channel I/O Module includes one 2 Gb, Short Wave, Small-Form-Factor-Pluggable Transceiver (SFP). A  
second msa Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used.  
msa Fibre Channel I/O Module  
DA-11621  
Canada — Version 2 April 15, 2003  
4
 
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
MSA1000 Components  
The HP StorageWorks msa Hub 2/3 is a low-cost interconnect designed for clustering or low cost, high speed  
attachment of two servers to the msa1000, an entry-level storage area network (SAN) solution. The msa Hub 2/3  
is a 3-port Fibre Channel Arbitrated Loop hub that is mounted on a blade that easily installs inside the msa1000  
storage unit, saving valuable rack space. Two of these hubs may be installed for redundancy within the msa1000.  
The msa Hub 2/3 is not cascadable.  
msa Hub 2/3  
The hub presents the user with two SFP ports for simple direct attachment to two single or clustered servers  
without having to purchase an external interconnect device. It offers the most cost-effective solution for a user to  
enable a clustered server environment.  
high-performance: supports msa1000 with a 2 Gb interconnect capable of 200 MB/s speed  
low cost: supports the entry-level SAN array with the most cost effective option for 2-node clustering  
compact: imbeds in the msa1000, replacing the I/O module, saving valuable rack space  
complete: comes with two SW SFPs – no need for further investment  
The hp StorageWorks msa SAN switch 2/8 ia a new optional switch embedded on a blade, for mounting internal  
to an msa1000. The msa SAN Switch 2/8 offers low price per port and full scalability, doing so while taking zero  
rack space, even in a redundant configuration. It ships with four SFPs installed. Because of its’ low cost per port it  
is the most cost effective method of enabling the larger SAN. It is interoperable with the hp line of SAN  
interconnect family of FC switches.  
msa SAN switch 2/8  
eight 2 Gb ports: 1 to controller, 7 user accessible  
product ships with 4 SFPs installed  
no E-port restriction, accepts all optional software  
interoperates with external SAN Switch 2 Gb switches  
configuration and management methodology common with SAN Switch product line, same methods as  
installed base of 30,000+ HP SAN Switches  
2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot  
plug into 2 Gb infrastructure components such as 2 Gb Fabric Switches. StorageWorks 2 Gb SFP SW  
Transceivers support distances up to 300 metres at 2 Gb and 500 metres at 1 Gb using multi-mode fiber optic  
cable.  
2 Gb Small Form Factor Pluggable  
(SFP) SW Transceiver Kit  
Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic  
interference. HP offers cables to connect the msa1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC  
to LC cables are used when connecting the msa1000 to other 2 Gb Fibre Channel components because both  
connections will utilize small form factor transceivers. LC to SC cables are used when connecting the msa1000 to  
1 Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers.  
Multi-Mode Fibre Channel Cables  
SOFTWARE COMPONENTS  
The command line interface (CLI) is used to configure and manage the MSA1000. Additionally, the CLI can be  
used to display system information and status. See the HP StorageWorks Modular SAN Array 1000 User Guide  
Command Line Interface (CLI)  
for more information on the CLI commands  
Tru64 UNIX v5.1A with PK4 and NHD6  
Tru64 UNIX v5.1B with IPK  
OS Support  
Tru64 UNIX Support  
OpenVMS Support  
OpenVMS v7.3-1 with TIMA (ECO) Kit  
OpenVMS v7.2-2 with TIMA (ECO) Kit  
OpenVMS v7.3 with TIMA (ECO) Kit  
DA-11621  
Canada — Version 2 April 15, 2003  
 
5
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Service & Support, CarePaq and Warranty Information  
The Storage Services Packaging takes the existing storage product along with the existing services and creates a  
Storage Service Packages  
package of the storage hardware and appropriate services. The increased level of support provides for a higher  
level of storage system availability for the customer. The package includes 24x7 support with a 4-hour response  
for 3 years as well as installation and startup service.  
Three-year Limited Warranty for msa1000s, Fibre Channel Cables and SFP Transceivers; 3 years parts  
exchange; 1 year labour; 1 year on-site; next business day response. Options for the msa1000 carry their own  
warranty. Refer to HP's Limited Warranty Statement for further details.  
Warranty  
Software Product Services  
Hardware Product Services  
HP warrants only that the Software media will be free of physical defects  
for a period of ninety (90) days from delivery.  
Service & Support, CarePaq and  
Warranty Information  
Upgrades to the 90 day media defect warranty are available as CarePaq  
services. These services are available to upgrade the warranty to (1 or 3)  
full year of 9 hours by 5 days (or 24x7) software advisory and remedial  
software telephone support, new version license rights, and media and  
documentation distribution service.  
Installation services  
On-site maintenance (includes warranty support)  
Response time upgrades during the warranty period  
Post-warranty coverage  
RAID setup and performance consulting via statement of work  
Migration service consulting via statement of work  
Installation and Startup  
Services  
The Installation and Startup Service package provides installation and  
configuration of HP StorageWorks products. Major categories of work could  
include:  
Pre-installation consulting and planning  
Hardware installation, configuration and verification  
RAID array configuration and initialization  
Installation, configuration and verification of StorageWorks software  
Service tools installed, configured and verified  
Customer orientation  
Warranty Upgrade Options  
Response – Upgrade on-site response from next business day to same  
day 4 hours  
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x  
7 days  
Duration – Select duration of coverage for a period of 1, 3, or 5 years  
DA-11621  
Canada — Version 2 April 15, 2003  
 
6
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Service & Support, CarePaq and Warranty Information  
9x5, Next Business Day, On-Site Coverage, 3 years  
9x5, 4-Hour Response, On-Site Coverage, 3 years  
24x7, 4-Hour Response, On-Site Coverage, 3 years  
9x5, Next Business Day, On-Site Coverage, 5 years  
9x5, 4-Hour Response, On-Site Coverage, 5 years  
24x7, 4-Hour Response, On-Site Coverage, 5 years  
Hardware Installation  
FM-FCXHW-36  
103840-002  
FM-FC4HR-36  
402165-002  
FM-FC724-36  
402164-002  
FM-FCXHW-60  
170183-002  
FM-FC4HR-60  
170185-002  
FM-FC724-60  
170187-002  
FM-FCINS-IN  
402162-002  
CarePaq Information  
Sample part numbers:  
CarePaq is defined as an upgrade to the product warranty attribute, available for a specific duration and  
hours of coverage.  
CarePaq is not available for less than the products warranty duration.  
CarePaq is available for sale anytime during the warranty period for most products, but the commencement  
date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase  
may be required.  
CarePaq services are prepaid.  
NOTE: For additional CarePaq (hardware & software) information, as well as orderable part numbers, please  
refer to the URL listed below:  
DA-11621  
Canada — Version 2 April 15, 2003  
7
 
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
STEP 1 – ORDER REQUIRED ITEMS  
HP StorageWorks Modular SAN Array 1000  
201723-B22  
Includes  
(1) msa1000 Controller with 256 MB cache  
(1) MSA Fibre Channel I/O Module with 2 Gb SFP SW Transceiver  
Redundant Hot Pluggable Power Supply/blower assemblies  
Universal Rackmounting Kit  
msa1000 Support CD & Documentation  
(2) Power cables  
(2) 3-ft VHDCI to VHDCI SCSI cables  
NOTE: Fibre Channel cables are ordered separately.  
DA-11621  
Canada — Version 2 April 15, 2003  
 
8
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
STEP 2 – SELECT OPTIONAL NON-REDUNDANT MSA1000 SYSTEM OPTIONS  
msa SAN Switch 2/8 (integrated) (Includes four 2Gb SFPs)  
288247-B21  
286763-B21  
msa Hub 2/3 (integrated) (Includes two 2 Gb SFP transceivers)  
NOTE: The msa Hub 2/3 has two external Fibre Channel ports, both of which already  
have 2 Gb transceivers installed. The msa SAN switch 2/8 has seven external  
ports, four of which have transceivers installed.  
DA-11621  
Canada — Version 2 April 15, 2003  
 
9
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
STEP 3 – CHOOS E REDUNDANT MSA1000 SYSTEM OPTIONS  
Redundant Configuration  
msa1000 Controller  
218231-B22  
NOTE: Redundant configurations require two Host Adapters per server, an additional  
controller for each server. Mixing of the msa Fibre Channel I/O Modular and the  
msa Hub 2/3 is not supported. When configuring the msa1000 for redundant  
controllers use either two msa Fibre Channel I/O Modules, two msa SAN switch  
2/8s, or two msa Hub 2/3s.  
msa Fibre Channel I/O Module (Includes 2 Gb SFP transceiver)  
msa Hub 2/3 (integrated) (Includes two 2Gb SFP transceivers)  
msa SAN Switch 2/8 (integrated) (Includes four 2Gb SFP transceivers)  
218960-B21  
286763-B21  
288247-B21  
DA-11621  
Canada — Version 2 April 15, 2003  
10  
 
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
STEP 4 – CHOOS E SUPPORTED OPTIONS FOR 2 GB OR 1 GB INFRAS TRUCTURE  
2 Gb SFP SW Transceiver Kit  
221470-B21  
2 Gb Fibre Channel Transceiver  
(SFP)  
NOTE: Infrastructure” switches above are interoperable only with HP StorageWorks  
MSA SAN Switch 2/8, SAN Switch 2/8EL, 2/16, 2/32, core 2/64 products and all  
Power Pak models. They are also interoperable with designated discontinued 1  
Gb SAN Switch models.  
2 Gb Fibre Channel Fabric  
“Infrastructure” family of  
switches  
HP StorageWorks core 2/64 PowerPak  
332178-B21  
254508-B21  
333764-B21  
240603-B21  
322119-B21  
322118-B21  
283056-B21  
322121-B21  
322120-B21  
288247-B21  
324504-B21  
324506-B21  
324507-B21  
324508-B21  
325891-B21  
324505-B21  
325892-B21  
HP StorageWorks core 2/64  
HP StorageWorks SAN Switch 2/32 PowerPak  
HP StorageWorks SAN Switch 2/32  
HP StorageWorks SAN Switch 2/16 PowerPak  
HP StorageWorks SAN Switch 2/16  
HP StorageWorks SAN Switch 2/16-EL  
HP StorageWorks SAN Switch 2/8 PowerPak  
HP StorageWorks SAN Switch 2/8-EL  
HP StorageWorks MSA SAN Switch 2/8 (Includes four 2 Gb SFP transceivers)  
Fabric Watch for 8 and 16 port switches  
ISL Trunking kit for 8 and 16 port switches  
Advanced Performance Monitor for 8 and 16 port switches  
Quick Loop for 8 and 16 port switches  
Remote Switch for 8 and 16 port switches  
Extended Fabric for 8 and 16 port switches  
HP StorageWorks PowerPak Bundle for 2 Gb Brocade Based 8 and 16 port  
Switches(Trunking, Perf Monitor, remote switch, fabric watch, extended fabric)  
HP Storageworks 2/8-EL Upgrade license  
325888-B21  
331148-B21  
330883-B21  
325887-B21  
325886-B21  
Optional Rack mount kit for SAN Switch 2/8-EL and SAN Switch 2/16  
Remote Switch for HP StorageWorks 2/64  
ISL trunking for HP StorageWorks 2/64  
Extended fabric for HP StorageWorks 2/64  
NOTE: High Availability” switches above are interoperable only with HP StorageWorks  
Director 2/140. Director 2/64, Edge Switch 2/32, Edge Switch 2/24, and the  
discontinued Edge Switch 2/16 products.  
2 Gb Fibre Channel Fabric  
Switches, “High Availability”  
family of switches  
HP StorageWorks Director 2/140 (64-ports active)  
HP StorageWorks director 2/64  
316094-B21  
286809-B21  
286810-B21  
302660-B21  
316095-B21  
316096--B21  
HP StorageWorks edge switch 2/32 (16 active ports)  
8-FlexPort upgrade for edge 2/32  
HP StorageWorks Edge switch 2/24 (8 ports active)  
8-FlexPort upgrade for edge 2/24  
MSA Hub 2/3 (integrated option, comes complete with two SFPs)  
286763-B21  
2 Gb Fibre Channel Integrated  
Hub  
DA-11621  
Canada — Version 2 April 15, 2003  
11  
 
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
STEP 4 – CHOOS E SUPPORTED OPTIONS FOR 2 GB OR 1 GB INFRAS TRUCTURE (continued)  
FCA2354 Host Adapter (Tru64 UNIX, OpenVMS)  
261329-B21  
2 Gb Fibre Channel HBAs  
Use 2 Gb Fibre Channel cables when connecting the msa Fibre Channel I/O Module or  
the msa Fabric Switch 6 to FCA2101 HBA(s)  
Fibre Channel Cables for 2 Gb  
Infrastructure  
2 m LC-LC Multi-Mode Fibre Channel Cable  
5 m LC-LC Multi-Mode Fibre Channel Cable  
15 m LC-LC Multi-Mode Fibre Channel Cable  
30 m LC-LC Multi-Mode Fibre Channel Cable  
50 m LC-LC Multi-Mode Fibre Channel Cable  
221692-B21  
221692-B22  
221692-B23  
221692-B26  
221692-B27  
Use 1 Gb Fibre Channel cables when connecting the msa Fibre Channel I/O Module  
and FCA2354 HBA(s) to 1 Gb fabric switches or hubs.  
Fibre Channel Cables for 1 Gb  
Fabric Switches and Hub  
2 m LC-SC Multi-Mode Fibre Channel Cable  
5 m LC-SC Multi-Mode Fibre Channel Cable  
15 m LC-SC Multi-Mode Fibre Channel Cable  
30 m LC-SC Multi-Mode Fibre Channel Cable  
50 m LC-SC Multi-Mode Fibre Channel Cable  
221691-B21  
221691-B22  
221691-B23  
221691-B26  
221691-B27  
STEP 5 – CHOOS E HARD DRIVES & STORAGEWORKS ENCLOSURES  
Hard Drives  
36.4 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1)  
72.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1)  
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1)  
18.2 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1)  
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1)  
72.8 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1)  
286713-B22  
286714-B22  
286716-B22  
286775-B22  
286776-B22  
286778-B22  
*NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3  
speeds.  
NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive  
Compatibility table located at: http://www.hp.com/.  
NOTE: This Web site is available in English only.  
DA-11621  
Canada — Version 2 April 15, 2003  
 
12  
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
STEP 5 – CHOOS E HARD DRIVES & STORAGEWORKS ENCLOSURES (continued)  
The msa1000 cabinet holds fourteen 1” Universal Drives. Add one StorageWorks  
Enclosure to increase capacity up to 28 drives. Add two HP StorageWorks Enclosures  
to increase capacity up to the maximum of 42 drives.  
StorageWorks Enclosures  
HP StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the  
msa1000)  
190209-001  
190211-001  
HP StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the  
msa1000)  
STEP 6 – CHOOSE RACK OPTIONS  
9142 Rack  
120663-B21, -B22, -B23  
120664-B21, -B22, -B23  
120665-B21, -B22, -B23  
222192-B21  
9136 Rack  
9122 Rack  
9842 Rack  
10647 (47U) rack  
10642 (42U) rack  
10636 (36U) rack  
10622 (22U) rack  
H9A10 Cab  
245160-B21, -B23  
245161-B21, -B22, -B23  
245162-B21, -B22, -B23  
245163-B21, -B22, -B23  
H9A10-XX  
H9A15 Cab  
H9A15-XX  
DA-11621  
Canada — Version 2 April 15, 2003  
 
13  
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Configuration Information  
CONFIGURATION EXAMPLES  
Two Node Redundant Cluster Solution  
Description  
HP StorageWorks Modular SAN Array 1000  
msa1000 Controller  
msa Hub 2/3  
Quantity  
Part Number  
201723-B22  
218231-B22  
286763-B21  
1
1
2
4
Host Adapter  
261329-B21  
4
14  
2 m LC-LC Multi-Mode Fibre Channel Cable  
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15K  
221692-B21  
286776-B21  
4 Host, 6TB, Redundant SAN Solution  
Description  
HP StorageWorks Modular SAN Array 1000  
msa1000 Controller  
256 MB Cache Modules for Controller (one additional for each controller)  
msa SAN Switch 2/8 (Includes four 2Gb SFP transceivers)  
Host Adapter (appropriate model for operating system)  
2 m LC-LC Multi-Mode Fibre Channel Cable  
StorageWorks Enclosure Model 4314R  
Quantity  
Part Number  
201723-B22  
218231-B22  
254786-B21  
288247-B21  
1
1
2
2
8
8
2
42  
221692-B21  
190209-001  
286716-B22  
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1)  
DA-11621  
Canada — Version 2 April 15, 2003  
 
14  
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Technical Specifications  
MODULAR SAN ARRAY 1000  
Power  
LED Indicators on Front (3)  
Fault detected in one or more sub-systems  
Fault in Enclosure Management  
Drive Access (centre)  
LED Indicators for Drive  
Modules (3)  
Online (left)  
Drive Failure (right)  
Power Supply/Blower Assembly Fault (1)  
EMU (3) Power, A bus, B bus  
Ultra3 SCSI to Hard Drives  
2 Gb Fibre Channel to Hosts  
LED Indicators on Rear Panel  
(4)  
Interface  
Fourteen, 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (msa1000 Cabinet); expandable to 42 using  
two additional StorageWorks 4200/4300 Enclosures  
Maximum Number of Drives  
Temperature Range  
Operating  
Shipping  
50° to 95°F/10° to 35°C  
–22° to 122°F/–30° to 50°C  
NOTE: Derated 1°C per 1,000 feet of elevation to 10,000 ft.  
Operating  
10% to 90%  
Up to 95%  
100 to 240 VAC  
50 to 60 Hz  
6 A Max  
Relative Humidity  
Non-operating  
Rated Input Voltage  
Rated Input Frequency  
Rated Input Current  
Input Power (max)  
1876 Btu/hr*  
Input Power Requirements  
549 W*  
Heat Dissipation (max)  
* Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full  
rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment  
configuration.  
4U Rack Form Factor  
msa1000 Cabinet  
Dimensions (H x W x D)  
Weight  
6.9 x 19 x 20.5 in/17.5 x 48.3 x 52.1 cm  
Net 55 to 85 lb/24.95 to 38.56 kg  
Dimensions (L x W x D)  
Weight  
28.5 x 14.81 x 33.13 in/72.4 x 37.6 x 84.1 cm  
Gross 75 to 105 lb/34.02 to 47.63 kg  
Shipping Packaging  
DA-11621  
Canada — Version 2 April 15, 2003  
 
15  
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Technical Specifications  
MODULAR SAN ARRAY 1000 CONTROLLER  
Controller Display with Status Indicators (2) and Push Buttons (4)  
User Interface  
Status Indicators on front of Controller (16)  
LVD (Low Voltage Differential)  
Wide Ultra3 SCSI (160 MB/s per channel)  
4-channel: 2 external/2 Internal  
Up to 42 drives  
Electrical Interface  
Protocol Support  
SCSI Ports  
Drives Supported  
Maximum Capacity  
Logical Drives  
6.0 TB (42 drives x 146 GB)  
Up to 32 logical drives  
RAID ADG (Advanced Data Guarding)  
RAID 5 (Distributed Data Guarding)  
RAID 1+0 (Striping & Mirroring)  
RAID 0 (Striping)  
RAID Support  
Up to 512 MB Read/Write (256-MB modules). Added cache size must match original and if a second controller is  
employed, it too must have equally configured cache.  
Cache Memory  
ECC protection, battery-backed, and removable  
Standard, starting November 19, 2002: 256 MB cache memory (single module)  
Up to three days of redundant battery life, removable for easy replacement  
2 MB flashable ROM  
Cache Batteries  
Upgradeable Firmware  
HP Ultra 320, Ultra3, and Ultra2 SCSI 1-inch Universal drives  
Disk Drive and Enclosure  
Protocol Support  
Dimensions (L x W x D)  
Weight  
17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm  
Gross 6 lb/2.72 kg  
Packaging  
MODULAR SAN ARRAY FIBRE CHANNEL I/O MODULE  
LC  
Connector Type  
One 2 Gb Fibre Channel Port using removable Small-Form-Factor-Pluggable Transceiver (SFP)  
Number of Fibre Channel Ports  
Bandwidth  
200 MB/s  
Fibre Channel Class 2 and 3 connectionless service  
Fibre Channel  
Operation Modes  
Protocols Supported  
Packaging  
Dimensions (L x W x D)  
Weight  
17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm  
Gross 6 lb/2.72 kg  
FCA2354 HOST ADAPTER  
LC  
Connector Type  
SCSI, IP  
Protocol  
64-bit/66 MHz PCI  
200 MB/s  
Data Transfer Method  
Maximum Transfer Rate  
Packaging  
Dimensions (L x W x D)  
Weight  
11 x 8.5 x 3 in/27.9 x 21.6 x 7.6 cm  
Gross 1 lb/0.45 kg  
DA-11621  
Canada — Version 2 April 15, 2003  
 
16  
hp StorageWorks  
modular SAN array 1000  
specific for Tru64 UNIX and OpenVMS only  
QuickSpecs  
Technical Specifications  
MULTI-MODE FIBRE CHANNEL CABLES KITS  
LC-LC (2 Gb to 2 Gb connections) and LC-SC (2 Gb to 1 Gb connections) 50 Micron multi-mode fibre  
6.5 ft, 16.4 ft, and 49.2 ft/2 m, 5 m, and 15 m  
Cable Type  
Available Cable Lengths  
Packaging  
Dimensions (L x W x D)  
Weight  
11.5 x 9 x 1.5 in/29.2 x 22.8 x 3.8 cm  
Gross 0.75 to 1 lb/0.34 to 0.45 kg  
© 2003 Compaq Canada Corp. (an HP Company) All rights reserved. Printed in Canada.  
Hewlett-Packard, the Hewlett-Packard logo, CarePaq, Open VMS, ProLiant, StorageWorks and Tru64 are trademarks of Hewlett-Packard Company in the  
U.S. and/or other countries. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. All other product names  
mentioned herein may be trademarks of their respective companies.  
Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided as is without warranty of any  
kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements  
accompanying such products. Nothing herein should be construed as constituting an additional warranty.  
DA-11621  
Canada — Version 2 April 15, 2003  
 
17  

Graco Stroller 1759724 User Manual
Grizzly Cordless Saw H0799 User Manual
Grizzly Planer Model G0550 User Manual
Grundig CRT Television MF 72 2410 7 TOP User Manual
Hamilton Electronics Microcassette Recorder HA 790 User Manual
Hans Grohe Plumbing Product 28570001 User Manual
Hearth and Home Technologies Indoor Fireplace 823 0170 User Manual
Heath Zenith Door 595 5684 09 User Manual
Honeywell Door RCW100KB User Manual
iHome Portable Speaker HM64 User Manual