Honeywell Refrigerator FG 701 User Manual

English  
FG-701 Glassbreak Simulator  
Note: Pressing the RED button again will deactivate the  
detector test mode. Test mode also turns off automatically  
after 5 to 10 minutes. (Refer to the detector’s installation  
instructions.)  
OPERATING INSTRUCTIONS  
WARNING: The FG-701 Simulator  
produces extremely loud sounds and  
can be hazardous to hearing when  
used at close range.  
Detector  
B
Never operate  
the FG-701  
when it is  
y detector  
pointed toward  
someone’s  
head.  
thest point of glass to be protected b  
r
a
F
This glassbreak simulator is for testing  
the range and function of all  
FlexGuard® glassbreak detectors.  
RED  
Button  
Most glassbreak models have the  
“Activate” test mode feature described  
below, including models:  
ACTIVATE  
TEST  
FLEX  
MAN  
FG10xx, FG15xx, FG16xx, FGW-15xx, 5853, FG8M, 5852H  
and others.  
Testing detector alarm function (FLEX mode):  
OPERATING THE SIMULATOR  
Important: If window coverings are present,  
In the following, "flex" refers to the low frequency sound  
caused by gently thumping the window and "audio" refers to  
the high frequency sound from the glassbreak simulator.  
If the detector range is adjustable, check that it is set correctly  
per the detector’s installation instructions.  
FlexGuard® glassbreak detectors with test mode must be in  
test mode for accurate testing with the FG-701. For those  
detectors, use Activate to start test mode. Refer to the  
detector’s installation instructions for test mode details.  
close them fully and hold the FG-701 behind the  
window coverings for testing.  
1. Set the FG-701 to TEST and FLEX. See B.  
2. Position the FG-701 near the farthest point of the protected  
glass, and point the speaker directly at the glassbreak  
detector.  
3. Press the RED button. The simulator will "click" and start an  
8-second armed period.  
4. Generate a flex signal by carefully thumping the glass with  
a cushioned tool. The FG-701 will respond by producing a  
burst of glass-break audio.  
If both the flex and audio are received properly, the red alarm  
LED on the detector will light, and the detector will send an  
alarm.  
Detector  
A
For all detectors that  
have test mode  
After the simulator is triggered by a flex signal, there is a one-  
second hold-off period during which the FG-701 will not trigger  
again. This prevents repeated triggering due to continued  
vibration of the glass.  
Successfully triggering the simulator with a flex signal  
generates a new 8-second armed period. If you do not  
generate a flex signal within 8 seconds, the simulator will  
automatically "click" off. Press the red button to re-arm the  
simulator.  
RED  
Button  
ACTIVATE  
TEST  
FLEX  
MAN  
The FG-701 may also be turned off by selecting MAN  
(manual) mode.  
To Activate glassbreak detector test mode:  
Testing detector range [MAN (manual) mode]:  
1. Install the glassbreak detector as per the detector’s  
installation instructions.  
2. Stand within 6' (2m) of the detector.  
If the glassbreak detector fails to signal an alarm when testing  
in the FLEX mode, switch the FG-701 to the MAN (manual)  
mode. Audio range can be tested independently in this mode.  
This will enable you to determine if the problem is flex or audio  
detection.  
3. Set the FG-701 to ACTIVATE and MAN (manual). See A.  
4. Aim the FG-701 speaker at the detector.  
5. Press the RED button for the ACTIVATE sound.  
The green LED will flash once per second to indicate the  
detector is in test mode.  
If test mode does not start, try again from a different position.  
- 1 -  
5-051-320-00 Rev. D  
 

Graco Car Seat 8482 User Manual
Graco Car Seat 8485 User Manual
Hamilton Beach Humidifier 840074800 User Manual
Hamilton Beach Juicer 67800 User Manual
Harbor Freight Tools Metal Detector 67378 User Manual
HP Hewlett Packard Computer Hardware c7000 User Manual
HP Hewlett Packard Network Router J8753A User Manual
Husqvarna Grinder PG680 User Manual
Hypertec Carrying Case N12308NHY User Manual
Igloo Beverage Dispenser FRW152 User Manual