®
CT87A,B,J Round Thermostat
LOW VOLTAGE (15 TO 30 VAC),
THERMOSTAT AND MOUNTING HARDWARE
Installation Instructions
Verify that you have the
correct thermostat
1
Using the compatibility chart
below, verify that you purchased
the correct CT87Thermostat for
your heating/cooling system. If
you are unsure which model is
right for your system, visit
yourhome or call Honeywell
Customer Care at
1-800-468-1502.
Compatible with:
Heating/Cooling system
CT87A CT87B CT87J
Heating only: Gas or oil fueled warm air, steam, or hot Yes
Yes
No
water heat
Cooling only: Electric air conditioning
Yes*
No
Yes
Yes
Yes
No
Heating and cooling: Gas or oil fueled warm air,
steam, or hot water heat with electric air conditioning
Single stage heat pump: Outdoor heating/cooling unit No
No
Yes
(compressor) with no auxiliary or backup heat.
Electric heat furnace with or without cooling:
No
No
No
Yes
No
Electric baseboard: Electric heating strips located just No
above the floor, usually 120-240 volts
Multistage: A conventional system with more than one No
stage, or an outdoor heating/cooling unit (compressor)
with auxiliary or backup heat.
No
No
* CT87A is compatible with 2-wire cooling-only systems.
® U.S. Registered Trademark
Copyright © 2002 Honeywell
All Rights Reserved
69-0274-6
CT87A,B,J ROUND® THERMOSTAT
5. Label the wires using the wiring
Fig. 2. Labeling wires.
labels that came with the CT87.
Identify each wire using the letter
of the terminal on the old thermo-
stat (Fig. 2). Do not label the wires
by color.
6. Disconnect the wires from the old
thermostat and wrap them around
a pencil to keep them from falling
back into the wall (Fig. 3).
M19086
Fig. 3. Wrapping wires.
WIRES THROUGH
WALL OPENING
MERCURY NOTICE
If this thermostat is replacing a
control that contains mercury in a
sealed tube, do not place your old
control in the trash. Contact your
local waste management authority
M20133
for instructions regarding recycling and the proper disposal of this
control, or of an old control containing mercury in a sealed tube.
Install the cover ring and wallplate or subbase
4
If installing on the wall
Refer to Fig. 4 as you work.
Fig. 4. Installing wallplate/subbase on the wall (wallplate shown).
COVER RING
WALLPLATE
THERMOSTAT
WIRING OPENING
NO. 4 X 1 INCH
SHEET METAL SCREWS (2)
M20188
3
69-0274-6
CT87A,B,J ROUND® THERMOSTAT
1. If using the cover ring: Position the cover ring against the wall so
that the arrow in the middle of the cover ring is pointing up.
2. Position the wallplate or subbase.
•
If using cover ring: Place the wallplate/subbase over the cover
ring. Rotate the wallplate/subbase until the wiring openings are
aligned and the two screw holes on the left and right side of the
wallplate/subbase align with the screw holes on the cover ring.
You will be inserting screws through these holes into the wall.
If attaching wallplate directly to the wall: Position so that the
UP indicator on the wallplate is on top.
•
•
If attaching subbase directly to the wall: Position so that the
fan and heating/cooling switches are on the top.
3. Use a pencil to mark the center of the screw holes on the left and
right sides of the wallplate or subbase.
4. Remove the wallplate/subbase and cover ring, and drill two 1/16-in.
holes at the locations you marked.
5. Reposition the cover ring (if used) and wallplate/subbase over the
holes, pull the wires through the wiring opening, and loosely insert
the two 1-in. screws into the drilled holes.
If installing on an outlet box
Refer to Fig. 5 as you work.
Fig. 5. Installing wallplate/subbase on an outlet box (subbase shown).
OUTLET BOX
1/2 IN. BINDING
HEAD SCREW (2)
1
2
COVER RING
SUBBASE
1/4 IN.
ROUND
HEAD
SCREW (2)
A
THERMOSTAT
WIRING HOLE
1
2
THE TWO INNER HOLES ARE USED WITH WALLPLATE.
IF OUTLET BOX IS HORIZONTAL, MOUNT COVER RING IN
POSITION SHOWN, BUT FASTEN WITH SCREWS THROUGH "A".
M20187
69-0274-6
4
CT87A,B,J ROUND® THERMOSTAT
1. Place the cover ring against the outlet box so that the arrow in the
middle of the cover ring is pointing up.
2. Pull the wires through the wiring hole on the bottom left side of the
cover ring.
3. Align the screw slots on the cover ring with the outlet box screw
holes, and attach the cover ring to the outlet box with two 1/2-in.
screws.
4. Place the wallplate or subbase over the cover ring so that the wiring
holes line up, and pull the wires through.
5. Loosely attach the wallplate/subbase to the cover ring with two 1/4-
in. screws, through the screw holes on the left and right sides of the
wallplate/subbase.
Level the wallplate or subbase
5
IMPORTANT: The wallplate/subbase must be level to maintain accu-
rate thermostat temperature.
1. Rotate the wallplate/subbase until level as shown in Fig. 6.
To level the subbase, use the leveling posts directly below the Heat
and Fan indicators.
Fig. 6. Leveling the wallplate.
SPIRIT
LEVEL
LEVELING
POSTS (2)
OPENING FOR
THERMOSTAT
WIRING
MOUNTING
SLOTS
M3319A
2. Tighten the mounting screws after making sure that the wallplate or
subbase is level.
5
69-0274-6
CT87A,B,J ROUND® THERMOSTAT
Wire the thermostat
6
1. Use the wiring cross-reference table below to match each old
thermostat wire with its corresponding terminal on the CT87 wallplate
or subbase. See Fig. 8 through 13 wiring diagrams.
Wiring Cross-reference
Connect to Connect to Connect to
Wire Label
R, RH, 4, V
Rc, R
CT87A
CT87B
CT87J
R
RH
R
Rc
W
W, W , H
W
Y
W
Y
1
Y, Y , M
Y
1
G, F
G
G
B
See Fig. 9
B*
O*
P
O
See Fig. 13
*Never attach wires to both the B and O terminals.
2. Strip the wire insulation as needed to fit the wires underneath the ter-
minal screws (Fig. 7).
Fig. 7. Fitting wires under the terminal screws.
FOR STRAIGHT
CONNECTION—
STRIP 5/16 in. [8 mm]
FOR WRAPAROUND
CONNECTION—
STRIP 7/16 in. [11 mm]
BARRIER
M1279
3. Loosen the terminal screws and slip each wire beneath its matching
terminal.
4. Securely tighten the terminal screws.
5. Push any excess wire back into the wall.
69-0274-6
6
CT87A,B,J ROUND® THERMOSTAT
Fig. 8. CT87A for a 2-wire heating only system.
CT87A WALLPLATE
POWER
R
TO
SYSTEM
Y
W
HEAT
M20183
Fig. 9. CT87A for a 3-wire hot water heating only system.
CT87A WALLPLATE
WIRE LABELS
(LETTERS
ON ORIGINAL
THERMOSTAT
TERMINALS)
R
R
3-WIRE
W
HOT WATER
ZONE VALVE
Y
W
B
M20184
Fig. 10. CT87B for a 4-wire heating/cooling system.
CT87B SUBBASE
POWER
FAN
TO
SYSTEM
RH
RC
G
COOL
Y
W
HEAT
M20185
JUMPER RH TO RC
7
69-0274-6
CT87A,B,J ROUND® THERMOSTAT
Fig. 11. CT87B for a 5-wire heating/cooling system.
CT87B SUBBASE
HEATING
POWER
TO
SYSTEM
FAN
RH
RC
G
COOLING
POWER
TO
SYSTEM
Y
W
COOL
HEAT
M20225
Fig. 12. CT87J for a 4-wire single stage heat pump.
CT87J SUBBASE
HEAT
FAN
TO
SYSTEM
W G
POWER
Y
P
COOL
REVERSING VALVE
R
O
B
HEAT
REVERSING VALVE
DO NOT ATTACH WIRES
TO BOTH B AND O
JUMPER W TO Y
M20186
Fig. 13. CT87J for 4-wire single stage heat pump.
CT87J SUBBASE
FAN
POWER
HEAT
REVERSING
VALVE
W
G
Y
1
P
COOL
REVERSING
VALVE
R
TO
SYSTEM
B
O
HEAT PUMP
COMPRESSOR
DO NOT ATTACH WIRES
TO BOTH B AND O
1
IF WIRES ARE ATTACHED TO Y OR W, AND P ON YOUR OLD
THERMOSTAT, CONTACT YOUR LOCAL CONTRACTOR FOR
FURTHER ASSISTANCE.
M20228
69-0274-6
8
CT87A,B,J ROUND® THERMOSTAT
Mount the thermostat
7
1. Pull off the thermostat cover and discard the red plastic insert that
holds the mercury switch in place during shipping.
2. Using a pencil point, slide the heat anticipator indicator to 1.2 on the
scale as shown in Fig. 14.
IMPORTANT: This prevents the thermostat from being damaged.
Fig. 14. Adjusting heat anticipator indicator.
HEAT ANTICIPATOR INDICATOR
1.2
.6
.5
.4
.3
.2
HOLE SUITABLE FOR
PENCIL POINT
.15
.12
.10
TO MOVE INDICATOR
SCALE
M20226
3. Place the thermostat over the wallplate or subbase so that the three
captive mounting screws align with the three raised screw holes on
the wallplate/subbase.
4. Tighten the three captive mounting screws as shown in Fig. 15.
NOTE: These screws complete the installation of the
thermostat.
Fig. 15. Tightening mounting screws.
CAPTIVE SCREWS (3)
M20227
9
69-0274-6
CT87A,B,J ROUND® THERMOSTAT
Set the heat anticipator for your system
8
IMPORTANT: Setting the heat anticipator allows the thermostat to
maintain accurate temperature control.
1. Using a pencil point, move the heat anticipator pointer to the number
that you recorded in Step 3, sub-step 3. If you could not find the
anticipator setting on the old thermostat, use the setting for your type
of system shown in the table below.
Your heating system: Heat anticipator setting:
Steam
1.2
0.8
0.8
0.4
0.3
Hot water heat
High-efficiency warm air
Standard warm air
Electric heat
2. Snap on the thermostat cover.
NOTE: If the furnace stays on beyond the thermostat set temperature,
move the anticipator pointer down by .1 ampere.
If the furnace shuts off before the set temperature is reached, move the
anticipator pointer up by .1 ampere.
Never adjust the anticipator below .3 ampere.
Check heating/cooling operation
9
Check heating
1. Turn the transparent dial to the farthest point left.
2. If your CT87 has a subbase, set the system switch to Heat.
3. Turn the dial until the temperature on the setting scale (Fig. 16)
exceeds the room temperature that is shown on the thermometer.
The heating system should start.
4. Turn the dial until the temperature on the setting scale is below the
room temperature that is shown on the thermometer.
The heating system should stop.
Fig. 16. Checking heating system.
SETTING SCALE
M9656
THERMOMETER
69-0274-6
10
CT87A,B,J ROUND® THERMOSTAT
Check cooling
IMPORTANT: To avoid damaging the compressor in the air conditioner,
do not operate the cooling system when the outdoor temperature is
below 50°F (10°C).
1. If your CT87 has a subbase, set the System switch on the left to
Cool.
IMPORTANT: After heating is tested, wait five minutes before switch-
ing to Cool on the CT87J model.
2. Lower the temperature setting below room temperature. The cooling
system should start.
3. Raise the temperature setting above room temperature. The cooling
system should stop.
Operation
To set the temperature, turn the dial until the pointer on the top setting scale aligns with
the desired temperature.
CT87B, J switches
Switch
Setting
Result
System Cool
The thermostat controls your cooling system.
Both the heating and cooling systems are off.
The thermostat controls your heating system.
The fan runs continuously.
Off
Heat
Fan
On
Auto
The fan runs only with the heating or cooling
system.
11
69-0274-6
CT87A,B,J ROUND® THERMOSTAT
Limited One-Year Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or
materials, under normal use and service, for a period of one (1) year from the date of purchase by
the consumer. If, at any time during the warranty period, the product is defective or malfunctions,
Honeywell shall repair or replace it (at Honeywell’s option) within a reasonable period of time.
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the retailer where you purchased
it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short
description of the malfunction, and mail it, postage prepaid, to the following address:
Honeywell Inc. USA
Honeywell Canada:
Dock 4 — MN10-3860
Honeywell Limited/Honeywell Limitée
35 Dynamic Drive
1985 Douglas Drive North
Golden Valley, MN 55422-3992
Scarborough, Ontario M1V 4Z9
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is
shown by Honeywell that the defect or malfunction was caused by damage which occurred while
the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated
above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND,
INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR
INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY
OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS
HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not
allow limitations on how long an implied warranty lasts, so the above limitation may not apply to
you.
This warranty gives you specific legal rights, and you may have other rights which vary from state
to state.
If you have any questions concerning this warranty, please write Honeywell Customer Care,
Honeywell Inc., 1985 Douglas Dr. N., Golden Valley, MN 55422-3992, or call 1-800-468-1502. In
Canada, write Retail Products ON15, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive,
Scarborough, Ontario M1V 4Z9.
Automation and Control Solutions
Honeywell
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
Golden Valley, MN 55422
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
69-0274-6 G.H. Rev. 08-02
|